Wind farm integration, scaled IEEE 33-bus system, harmonic distortion, power quality, voltage stability, agricultural distribution system, reliability indices, SAIDI/SAIFI, backward-forward sweep, renewable energy, multiobjective optimization, voltage reg
This research presents a systematic analysis framework for wind farm integration in scaled IEEE 33-bus agricultural distribution systems (×26.38, representing 98 MW peak agricultural load), focusing on comprehensive power quality, reliability, and economic assessment. The scaled system exhibits baseline voltage violations (24 buses) characteristic of extended radial distribution topologies serving concentrated agricultural loads, consistent with real utility system characteristics in Indonesian agricultural regions. Four wind penetration scenarios (0%, 15%, 30%, 45%) are evaluated using an integrated backward-forward sweep methodology coupling fundamental power flow with empirical harmonic calculations validated against full harmonic load flow analysis (±0.3% accuracy). The analysis employs realistic harmonic injection models for VFD-dominated agricultural loads and full-converter wind turbines, time-domain operational profiles capturing diurnal variations, and revised reliability modeling incorporating protection coordination constraints and battery energy storage system limitations. Results demonstrate that 30% penetration achieves optimal multi-objective performance validated through systematic sensitivity analysis across 10-45% penetration levels: active power loss reduction of 35.5% (210.9 kW to 136.1 kW), harmonic distortion mitigation up to 46.1% THD_V reduction at the wind connection point (1.52% to 0.82%), and realistic reliability improvements of 5.0% SAIDI reduction (8.52 to 8.09 hours/year) accounting for islanding effectiveness constraints (19% successful islanding events with proper battery energy storage and protection infrastructure). The 45% penetration scenario introduces voltage regulation challenges (V_max = 1.052 p.u.) that offset incremental benefits. Economic analysis reveals that system-wide benefits (loss reduction: $670,000/year) substantially exceed agricultural productivity gains ($4,800/year with realistic nonlinear yield models), positioning wind integration as primarily a power quality and efficiency enhancement with supplementary agricultural reliability benefits. Practical implementation requires comprehensive voltage regulation equipment ($2.1-2.5M investment), harmonic filters for VFD-dominated buses ($240,000), and advanced protection schemes for islanding operation ($450,000-$700,000). The integrated analysis framework provides utilities and agricultural operators with quantitative guidance for optimal distributed generation deployment, balancing technical performance, economic viability, and operational constraints.
Sofyan Sofyan, Jasrul Jamani Jamian, Norazliani Md Sapari, Ahmad Fudholi, Muhira Dzar Faraby, "Identifying Optimal Wind Penetration for Agricultural Distribution Networks: Integrated Power Quality and Reliability Analysis", International Journal of Engineering and Manufacturing (IJEM), Vol.16, No.2, pp.1-28, 2026. DOI:10.5815/ijem.2026.02.01
[1]M. E. Baran and F. F. Wu, "Network reconfiguration in distribution systems for loss reduction and load balancing," IEEE Transactions on Power Delivery, vol. 4, no. 2, pp. 1401-1407, 1989, doi: 10.1109/61.25627.
[2]T. Jen-Hao, "A direct approach for distribution system load flow solutions," IEEE Transactions on Power Delivery, vol. 18, no. 3, pp. 882-887, 2003, doi: 10.1109/TPWRD.2003.813818.
[3]J. H. Teng and C. Y. Chang, "Backward/Forward Sweep-Based Harmonic Analysis Method for Distribution Systems," IEEE Transactions on Power Delivery, vol. 22, no. 3, pp. 1665-1672, 2007, doi: 10.1109/TPWRD.2007.899523.
[4]S. D. Ahmed, F. S. M. Al-Ismail, M. Shafiullah, F. A. Al-Sulaiman, and I. M. El-Amin, "Grid Integration Challenges of Wind Energy: A Review," IEEE Access, vol. 8, pp. 10857-10878, 2020, doi: 10.1109/ACCESS.2020.2964896.
[5]"IEEE Standard for Harmonic Control in Electric Power Systems," IEEE Std 519-2022 (Revision of IEEE Std 519-2014), pp. 1-31, 2022, doi: 10.1109/IEEESTD.2022.9848440.
[6]D. Wu et al., "Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission," IEEE Open Journal of Power Electronics, vol. 5, pp. 583-604, 2024, doi: 10.1109/OJPEL.2024.3390417.
[7]J. Kaur and S. K. Bath, "Harmonic distortion in power systems due to electronic control and renewable energy integration: a comprehensive review," Discover Electronics, vol. 2, no. 1, p. 67, 2025/08/23 2025, doi: 10.1007/s44291-025-00111-9.
[8]W. I. Gabr and W. A. Salem, "Impact of Grid Connected Photovoltaic System on Total Harmonics Distortion (THD) of Low Voltage Distribution Network: A Case Study," in 2018 Twentieth International Middle East Power Systems Conference (MEPCON), 18-20 Dec. 2018 2018, pp. 608-614, doi: 10.1109/MEPCON.2018.8635216.
[9]J. C. Peña and G. A. O. Pinto, "Probabilistic and Harmonic Assessment of Power Quality Parameters from Distributed Energy Resources in a Distribution Network," TecnoLógicas, no. 59, p. 2684, 2024.
[10]N. Du, F. Tang, Y. Zhang, X. Gao, B. Hu, and Y. Zhang, "Research on the Impact of Integrated Wind Farm on Static Voltage Stability of Power System," in 2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2), 30 Oct.-1 Nov. 2020 2020, pp. 3993-3997, doi: 10.1109/EI250167.2020.9347376.
[11]I. K. Otchere, B. Arhin, K. A. Kyeremeh, and E. A. Frimpong, "Investigation of Voltage Stability for Transmission Network with High Penetration of Wind Energy Sources," in 2020 IEEE PES/IAS PowerAfrica, 25-28 Aug. 2020 2020, pp. 1-5, doi: 10.1109/PowerAfrica49420.2020.9219937.
[12]T. M. L. Assis, D. M. FalcÃo, and G. N. Taranto, "Dynamic Transmission Capability Calculation Using Integrated Analysis Tools and Intelligent Systems," IEEE Transactions on Power Systems, vol. 22, no. 4, pp. 1760-1770, 2007, doi: 10.1109/TPWRS.2007.907534.
[13]A. Khan, S. Memon, and T. P. Sattar, "Analyzing Integrated Renewable Energy and Smart-Grid Systems to Improve Voltage Quality and Harmonic Distortion Losses at Electric-Vehicle Charging Stations," IEEE Access, vol. 6, pp. 26404-26415, 2018, doi: 10.1109/ACCESS.2018.2830187.
[14]"IEEE Guide for Electric Power Distribution Reliability Indices - Redline," IEEE Std 1366-2012 (Revision of IEEE Std 1366-2003) - Redline, pp. 1-92, 2012.
[15]Renewable Energy and Agri-food Systems: Advancing Energy and Food Security towards Sustainable Development Goals. 2021.
[16]L. G. Tapia Carpio and F. A. Cardoso Guimarães, "Regional diversification of hydro, wind, and solar generation potential: A mean-variance model to stabilize power fluctuations in the Brazilian integrated electrical energy transmission and distribution system," Renew. Energy, vol. 235, p. 121266, 2024/11/01/ 2024, doi: https://doi.org/10.1016/j.renene.2024.121266.
[17]M. A. Abdelhamid, T. K. Abdelkader, H. A. A. Sayed, Z. Zhang, X. Zhao, and M. F. Atia, "Design and evaluation of a solar powered smart irrigation system for sustainable urban agriculture," Scientific Reports, vol. 15, no. 1, p. 11761, 2025/04/06 2025, doi: 10.1038/s41598-025-94251-3.
[18]M. B. Anwar et al., "Assessing the value of electric vehicle managed charging: a review of methodologies and results," Energy & Environmental Science, 10.1039/D1EE02206G vol. 15, no. 2, pp. 466-498, 2022, doi: 10.1039/D1EE02206G.